The Aurora 5 kW is a winner for the installer, electrician, and user. The screen has system controller for custom voltages. The dual inputs are shown on the photo. As soon as we opened the dc disconnect the light came on! Italian engineereed technology should be functioning for no less than 10 years warranty. The payback is at 5 years, the parts are recyclable. The panels will most likely see another inverter.
Friday, March 4, 2011
Saturday, January 22, 2011
Monday, January 17, 2011
Heliodyne Hot Water Part 1
This diagram explains the process from cold water to solar generated hot water. The heat exchanger & combo valve heats and moves water to the house or bottom of the tank. Please read the diagram to help explain the process of thermoexchange.
PV generator main panel connection diagram
The diagram shows four #8 conductors in split phase 240 vAC. The Green and white conductors are tapped into the ground busbar. The #6 EGC is also tapped into the ground busbar, which grounds the N, and Equipment ground. The red and black split phase is tapped into the 1/0 black and red using a compression tap.
Thursday, December 16, 2010
36 Panel Job in Kaneohe
This Job was a bit more customized because the roof was not plumb and old. We had to reinforce the mounting structure with U-strut. The panels were spaced from left to right, 2, 5, and 5 due to the vent pipes. The array has two strings of 12 panels. Surprisingly, the roof looks alot better with the panels.
On this roof, we can see the conduit with four conductor awg #14. The array has 12 sanyo with microinverters. The cable coming from the last inverter is attached with the line side #14s' to a double pull switch. The switch has metal, therefore, a ground green is attached to the switch housing. The line side has both the black and red. The load side or PV source side attaches to the other side. Enjoy
Tuesday, August 17, 2010
Sunset Beach PV Install (Sanyo 215 Watt)
This array has twenty 215 Watt Sanyo panels wired in two strings. Enphase inverters are connected to each panel. This simple plug and play wiring was easy except for the grouding. Due to the fact that every inverter must be tagged with #6 copper, it was a bit much. But other than that the system was pretty straight forward. This picture shows four rows of five. The A and B string were designed to run up to the JBox to prevent any need for whips. Enjoy sunset beach and PV. Sexy